Details
The procedure requires working with the IC177 module's PCB on the bench, unsoldering a few capacitors, and soldering the wires to the CB501 cable onto it. Wiring diagrams will be available in the software. In order to connect to the IC177 cluster, you will need the ZN085 RH850/V850Programmer and the ZN092 adapter.
In case you encounter a module where different wiring is needed, please contact [email protected], and they will provide additional diagrams.
The use of the ZN092 adapter is MANDATORY to ensure the safe completion of the procedure. ABRITES will not be held responsible for any technical issues or PCB damage resulting from the use of the MN037 without the ZN092 adapter.
AVDI and Active AMS are required!